dragonpilot - 基於 openpilot 的開源駕駛輔助系統
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

222 lines
10 KiB

#!/usr/bin/env python3
import unittest
from unittest.mock import patch
from parameterized import parameterized
from cereal import log
import cereal.messaging as messaging
from common.params import Params
params = Params()
# Create fake time
ssb = 0
def mock_sec_since_boot():
global ssb
ssb += 1
return ssb
with patch("common.realtime.sec_since_boot", new=mock_sec_since_boot):
with patch("common.params.put_nonblocking", new=params.put):
from selfdrive.thermald.power_monitoring import PowerMonitoring, CAR_BATTERY_CAPACITY_uWh, \
PANDA_OUTPUT_VOLTAGE, CAR_CHARGING_RATE_W, \
VBATT_PAUSE_CHARGING
def actual_current_to_panda_current(actual_current):
return max(int(((3.3 - (actual_current * 8.25)) * 4096) / 3.3), 0)
TEST_DURATION_S = 50
ALL_PANDA_TYPES = [(hw_type,) for hw_type in [log.HealthData.HwType.whitePanda,
log.HealthData.HwType.greyPanda,
log.HealthData.HwType.blackPanda,
log.HealthData.HwType.uno]]
def pm_patch(name, value, constant=False):
if constant:
return patch(f"selfdrive.thermald.power_monitoring.{name}", value)
return patch(f"selfdrive.thermald.power_monitoring.{name}", return_value=value)
class TestPowerMonitoring(unittest.TestCase):
def setUp(self):
# Clear stored capacity before each test
params.delete("CarBatteryCapacity")
params.delete("DisablePowerDown")
def mock_health(self, ignition, hw_type, car_voltage=12, current=0):
health = messaging.new_message('health')
health.health.hwType = hw_type
health.health.voltage = car_voltage * 1e3
health.health.current = actual_current_to_panda_current(current)
health.health.ignitionLine = ignition
health.health.ignitionCan = False
return health
# Test to see that it doesn't do anything when health is None
def test_health_present(self):
pm = PowerMonitoring()
for _ in range(10):
pm.calculate(None)
self.assertEqual(pm.get_power_used(), 0)
self.assertEqual(pm.get_car_battery_capacity(), (CAR_BATTERY_CAPACITY_uWh / 10))
# Test to see that it doesn't integrate offroad when ignition is True
@parameterized.expand(ALL_PANDA_TYPES)
def test_offroad_ignition(self, hw_type):
pm = PowerMonitoring()
for _ in range(10):
pm.calculate(self.mock_health(True, hw_type))
self.assertEqual(pm.get_power_used(), 0)
# Test to see that it integrates with white/grey panda while charging
@parameterized.expand([(log.HealthData.HwType.whitePanda,), (log.HealthData.HwType.greyPanda,)])
def test_offroad_integration_white(self, hw_type):
with pm_patch("get_battery_voltage", 4e6), pm_patch("get_battery_current", 1e5), pm_patch("get_battery_status", "Charging"):
pm = PowerMonitoring()
for _ in range(TEST_DURATION_S + 1):
pm.calculate(self.mock_health(False, hw_type, current=0.1))
expected_power_usage = ((TEST_DURATION_S/3600) * (0.1 * PANDA_OUTPUT_VOLTAGE) * 1e6)
self.assertLess(abs(pm.get_power_used() - expected_power_usage), 10)
# Test to see that it integrates with discharging battery
@parameterized.expand(ALL_PANDA_TYPES)
def test_offroad_integration_discharging(self, hw_type):
BATT_VOLTAGE = 4
BATT_CURRENT = 1
with pm_patch("get_battery_voltage", BATT_VOLTAGE * 1e6), pm_patch("get_battery_current", BATT_CURRENT * 1e6), \
pm_patch("get_battery_status", "Discharging"):
pm = PowerMonitoring()
for _ in range(TEST_DURATION_S + 1):
pm.calculate(self.mock_health(False, hw_type))
expected_power_usage = ((TEST_DURATION_S/3600) * (BATT_VOLTAGE * BATT_CURRENT) * 1e6)
self.assertLess(abs(pm.get_power_used() - expected_power_usage), 10)
# Test to check positive integration of car_battery_capacity
@parameterized.expand(ALL_PANDA_TYPES)
def test_car_battery_integration_onroad(self, hw_type):
BATT_VOLTAGE = 4
BATT_CURRENT = 1
with pm_patch("get_battery_voltage", BATT_VOLTAGE * 1e6), pm_patch("get_battery_current", BATT_CURRENT * 1e6), \
pm_patch("get_battery_status", "Discharging"):
pm = PowerMonitoring()
pm.car_battery_capacity_uWh = 0
for _ in range(TEST_DURATION_S + 1):
pm.calculate(self.mock_health(True, hw_type))
expected_capacity = ((TEST_DURATION_S/3600) * CAR_CHARGING_RATE_W * 1e6)
self.assertLess(abs(pm.get_car_battery_capacity() - expected_capacity), 10)
# Test to check positive integration upper limit
@parameterized.expand(ALL_PANDA_TYPES)
def test_car_battery_integration_upper_limit(self, hw_type):
BATT_VOLTAGE = 4
BATT_CURRENT = 1
with pm_patch("get_battery_voltage", BATT_VOLTAGE * 1e6), pm_patch("get_battery_current", BATT_CURRENT * 1e6), \
pm_patch("get_battery_status", "Discharging"):
pm = PowerMonitoring()
pm.car_battery_capacity_uWh = CAR_BATTERY_CAPACITY_uWh - 1000
for _ in range(TEST_DURATION_S + 1):
pm.calculate(self.mock_health(True, hw_type))
estimated_capacity = CAR_BATTERY_CAPACITY_uWh + (CAR_CHARGING_RATE_W / 3600 * 1e6)
self.assertLess(abs(pm.get_car_battery_capacity() - estimated_capacity), 10)
# Test to check negative integration of car_battery_capacity
@parameterized.expand(ALL_PANDA_TYPES)
def test_car_battery_integration_offroad(self, hw_type):
BATT_VOLTAGE = 4
BATT_CURRENT = 1
with pm_patch("get_battery_voltage", BATT_VOLTAGE * 1e6), pm_patch("get_battery_current", BATT_CURRENT * 1e6), \
pm_patch("get_battery_status", "Discharging"):
pm = PowerMonitoring()
pm.car_battery_capacity_uWh = CAR_BATTERY_CAPACITY_uWh
for _ in range(TEST_DURATION_S + 1):
pm.calculate(self.mock_health(False, hw_type))
expected_capacity = CAR_BATTERY_CAPACITY_uWh - ((TEST_DURATION_S/3600) * (BATT_VOLTAGE * BATT_CURRENT) * 1e6)
self.assertLess(abs(pm.get_car_battery_capacity() - expected_capacity), 10)
# Test to check negative integration lower limit
@parameterized.expand(ALL_PANDA_TYPES)
def test_car_battery_integration_lower_limit(self, hw_type):
BATT_VOLTAGE = 4
BATT_CURRENT = 1
with pm_patch("get_battery_voltage", BATT_VOLTAGE * 1e6), pm_patch("get_battery_current", BATT_CURRENT * 1e6), \
pm_patch("get_battery_status", "Discharging"):
pm = PowerMonitoring()
pm.car_battery_capacity_uWh = 1000
for _ in range(TEST_DURATION_S + 1):
pm.calculate(self.mock_health(False, hw_type))
estimated_capacity = 0 - ((1/3600) * (BATT_VOLTAGE * BATT_CURRENT) * 1e6)
self.assertLess(abs(pm.get_car_battery_capacity() - estimated_capacity), 10)
# Test to check policy of stopping charging after MAX_TIME_OFFROAD_S
@parameterized.expand(ALL_PANDA_TYPES)
def test_max_time_offroad(self, hw_type):
global ssb
BATT_VOLTAGE = 4
BATT_CURRENT = 0 # To stop shutting down for other reasons
MOCKED_MAX_OFFROAD_TIME = 3600
with pm_patch("get_battery_voltage", BATT_VOLTAGE * 1e6), pm_patch("get_battery_current", BATT_CURRENT * 1e6), \
pm_patch("get_battery_status", "Discharging"), pm_patch("MAX_TIME_OFFROAD_S", MOCKED_MAX_OFFROAD_TIME, constant=True):
pm = PowerMonitoring()
pm.car_battery_capacity_uWh = CAR_BATTERY_CAPACITY_uWh
start_time = ssb
health = self.mock_health(False, hw_type)
while ssb <= start_time + MOCKED_MAX_OFFROAD_TIME:
pm.calculate(health)
if (ssb - start_time) % 1000 == 0 and ssb < start_time + MOCKED_MAX_OFFROAD_TIME:
self.assertFalse(pm.should_disable_charging(health, start_time))
self.assertTrue(pm.should_disable_charging(health, start_time))
# Test to check policy of stopping charging when the car voltage is too low
@parameterized.expand(ALL_PANDA_TYPES)
def test_car_voltage(self, hw_type):
global ssb
BATT_VOLTAGE = 4
BATT_CURRENT = 0 # To stop shutting down for other reasons
TEST_TIME = 100
with pm_patch("get_battery_voltage", BATT_VOLTAGE * 1e6), pm_patch("get_battery_current", BATT_CURRENT * 1e6), \
pm_patch("get_battery_status", "Discharging"):
pm = PowerMonitoring()
pm.car_battery_capacity_uWh = CAR_BATTERY_CAPACITY_uWh
health = self.mock_health(False, hw_type, car_voltage=(VBATT_PAUSE_CHARGING - 1))
for i in range(TEST_TIME):
pm.calculate(health)
if i % 10 == 0:
self.assertEqual(pm.should_disable_charging(health, ssb), (pm.car_voltage_mV < VBATT_PAUSE_CHARGING*1e3))
self.assertTrue(pm.should_disable_charging(health, ssb))
# Test to check policy of not stopping charging when DisablePowerDown is set
def test_disable_power_down(self):
global ssb
BATT_VOLTAGE = 4
BATT_CURRENT = 0 # To stop shutting down for other reasons
TEST_TIME = 100
params.put("DisablePowerDown", b"1")
with pm_patch("get_battery_voltage", BATT_VOLTAGE * 1e6), pm_patch("get_battery_current", BATT_CURRENT * 1e6), \
pm_patch("get_battery_status", "Discharging"):
pm = PowerMonitoring()
pm.car_battery_capacity_uWh = CAR_BATTERY_CAPACITY_uWh
health = self.mock_health(False, log.HealthData.HwType.uno, car_voltage=(VBATT_PAUSE_CHARGING - 1))
for i in range(TEST_TIME):
pm.calculate(health)
if i % 10 == 0:
self.assertFalse(pm.should_disable_charging(health, ssb))
self.assertFalse(pm.should_disable_charging(health, ssb))
# Test to check policy of not stopping charging when ignition
def test_ignition(self):
global ssb
BATT_VOLTAGE = 4
BATT_CURRENT = 0 # To stop shutting down for other reasons
TEST_TIME = 100
with pm_patch("get_battery_voltage", BATT_VOLTAGE * 1e6), pm_patch("get_battery_current", BATT_CURRENT * 1e6), \
pm_patch("get_battery_status", "Discharging"):
pm = PowerMonitoring()
pm.car_battery_capacity_uWh = CAR_BATTERY_CAPACITY_uWh
health = self.mock_health(True, log.HealthData.HwType.uno, car_voltage=(VBATT_PAUSE_CHARGING - 1))
for i in range(TEST_TIME):
pm.calculate(health)
if i % 10 == 0:
self.assertFalse(pm.should_disable_charging(health, ssb))
self.assertFalse(pm.should_disable_charging(health, ssb))
if __name__ == "__main__":