You can not select more than 25 topics
			Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
		
		
		
		
		
			
		
			
				
					
					
						
							88 lines
						
					
					
						
							2.8 KiB
						
					
					
				
			
		
		
	
	
							88 lines
						
					
					
						
							2.8 KiB
						
					
					
				| import os
 | |
| import subprocess
 | |
| import time
 | |
| import unittest
 | |
| 
 | |
| from multiprocessing import Queue
 | |
| 
 | |
| from cereal import messaging
 | |
| from openpilot.common.basedir import BASEDIR
 | |
| 
 | |
| SIM_DIR = os.path.join(BASEDIR, "tools/sim")
 | |
| 
 | |
| class TestSimBridgeBase(unittest.TestCase):
 | |
|   @classmethod
 | |
|   def setUpClass(cls):
 | |
|     if cls is TestSimBridgeBase:
 | |
|       raise unittest.SkipTest("Don't run this base class, run test_carla_bridge.py instead")
 | |
| 
 | |
|   def setUp(self):
 | |
|     self.processes = []
 | |
| 
 | |
|   def test_engage(self):
 | |
|     # Startup manager and bridge.py. Check processes are running, then engage and verify.
 | |
|     p_manager = subprocess.Popen("./launch_openpilot.sh", cwd=SIM_DIR)
 | |
|     self.processes.append(p_manager)
 | |
| 
 | |
|     sm = messaging.SubMaster(['controlsState', 'carEvents', 'managerState'])
 | |
|     q = Queue()
 | |
|     carla_bridge = self.create_bridge()
 | |
|     p_bridge = carla_bridge.run(q, retries=10)
 | |
|     self.processes.append(p_bridge)
 | |
| 
 | |
|     max_time_per_step = 60
 | |
| 
 | |
|     # Wait for bridge to startup
 | |
|     start_waiting = time.monotonic()
 | |
|     while not carla_bridge.started and time.monotonic() < start_waiting + max_time_per_step:
 | |
|       time.sleep(0.1)
 | |
|     self.assertEqual(p_bridge.exitcode, None, f"Bridge process should be running, but exited with code {p_bridge.exitcode}")
 | |
| 
 | |
|     start_time = time.monotonic()
 | |
|     no_car_events_issues_once = False
 | |
|     car_event_issues = []
 | |
|     not_running = []
 | |
|     while time.monotonic() < start_time + max_time_per_step:
 | |
|       sm.update()
 | |
| 
 | |
|       not_running = [p.name for p in sm['managerState'].processes if not p.running and p.shouldBeRunning]
 | |
|       car_event_issues = [event.name for event in sm['carEvents'] if any([event.noEntry, event.softDisable, event.immediateDisable])]
 | |
| 
 | |
|       if sm.all_alive() and len(car_event_issues) == 0 and len(not_running) == 0:
 | |
|         no_car_events_issues_once = True
 | |
|         break
 | |
| 
 | |
|     self.assertTrue(no_car_events_issues_once,
 | |
|                     f"Failed because no messages received, or CarEvents '{car_event_issues}' or processes not running '{not_running}'")
 | |
| 
 | |
|     start_time = time.monotonic()
 | |
|     min_counts_control_active = 100
 | |
|     control_active = 0
 | |
| 
 | |
|     while time.monotonic() < start_time + max_time_per_step:
 | |
|       sm.update()
 | |
| 
 | |
|       q.put("cruise_down")  # Try engaging
 | |
| 
 | |
|       if sm.all_alive() and sm['controlsState'].active:
 | |
|         control_active += 1
 | |
| 
 | |
|         if control_active == min_counts_control_active:
 | |
|           break
 | |
| 
 | |
|     self.assertEqual(min_counts_control_active, control_active, f"Simulator did not engage a minimal of {min_counts_control_active} steps was {control_active}")
 | |
| 
 | |
|   def tearDown(self):
 | |
|     print("Test shutting down. CommIssues are acceptable")
 | |
|     for p in reversed(self.processes):
 | |
|       p.terminate()
 | |
| 
 | |
|     for p in reversed(self.processes):
 | |
|       if isinstance(p, subprocess.Popen):
 | |
|         p.wait(15)
 | |
|       else:
 | |
|         p.join(15)
 | |
| 
 | |
| 
 | |
| if __name__ == "__main__":
 | |
|   unittest.main()
 | |
| 
 |