					@ -15,7 +15,7 @@ def mock_sec_since_boot(): | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					with patch("common.realtime.sec_since_boot", new=mock_sec_since_boot): | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					  with patch("common.params.put_nonblocking", new=params.put): | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					    from selfdrive.thermald.power_monitoring import PowerMonitoring, CAR_BATTERY_CAPACITY_uWh, \ | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					                                                    CAR_CHARGING_RATE_W, VBATT_PAUSE_CHARGING | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					                                                    CAR_CHARGING_RATE_W, VBATT_PAUSE_CHARGING, DELAY_SHUTDOWN_TIME_S | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					
 | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					TEST_DURATION_S = 50 | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					GOOD_VOLTAGE = 12 * 1e3 | 
				
			
			
		
	
	
		
			
				
					| 
						
							
								
							
						
						
							
								
							
						
						
					 | 
				
				 | 
				 | 
				
					@ -116,10 +116,9 @@ class TestPowerMonitoring(unittest.TestCase): | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					          self.assertFalse(pm.should_shutdown(ignition, True, start_time, False)) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					      self.assertTrue(pm.should_shutdown(ignition, True, start_time, False)) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					
 | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					  # Test to check policy of stopping charging when the car voltage is too low | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					  def test_car_voltage(self): | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					    POWER_DRAW = 0 # To stop shutting down for other reasons | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					    TEST_TIME = 100 | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					    TEST_TIME = 350 | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					    VOLTAGE_SHUTDOWN_MIN_OFFROAD_TIME_S = 50 | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					    with pm_patch("VOLTAGE_SHUTDOWN_MIN_OFFROAD_TIME_S", VOLTAGE_SHUTDOWN_MIN_OFFROAD_TIME_S, constant=True), pm_patch("HARDWARE.get_current_power_draw", POWER_DRAW): | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					      pm = PowerMonitoring() | 
				
			
			
		
	
	
		
			
				
					| 
						
						
						
							
								
							
						
					 | 
				
				 | 
				 | 
				
					@ -130,8 +129,9 @@ class TestPowerMonitoring(unittest.TestCase): | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					        pm.calculate(VOLTAGE_BELOW_PAUSE_CHARGING, ignition) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					        if i % 10 == 0: | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					          self.assertEqual(pm.should_shutdown(ignition, True, start_time, True), | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					                           (pm.car_voltage_mV < VBATT_PAUSE_CHARGING*1e3 and | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					                            (ssb - start_time) > VOLTAGE_SHUTDOWN_MIN_OFFROAD_TIME_S)) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					                           (pm.car_voltage_mV < VBATT_PAUSE_CHARGING * 1e3 and | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					                            (ssb - start_time) > VOLTAGE_SHUTDOWN_MIN_OFFROAD_TIME_S and | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					                             (ssb - start_time) > DELAY_SHUTDOWN_TIME_S)) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					      self.assertTrue(pm.should_shutdown(ignition, True, start_time, True)) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					
 | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					  # Test to check policy of not stopping charging when DisablePowerDown is set | 
				
			
			
		
	
	
		
			
				
					| 
						
							
								
							
						
						
							
								
							
						
						
					 | 
				
				 | 
				 | 
				
					@ -177,6 +177,26 @@ class TestPowerMonitoring(unittest.TestCase): | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					        if i % 10 == 0: | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					          self.assertFalse(pm.should_shutdown(ignition, False, ssb, False)) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					      self.assertFalse(pm.should_shutdown(ignition, False, ssb, False)) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					       | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					  def test_delay_shutdown_time(self): | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					    pm = PowerMonitoring() | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					    pm.car_battery_capacity_uWh = 0 | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					    ignition = False | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					    in_car = True  | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					    offroad_timestamp = ssb | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					    started_seen = True | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					    pm.calculate(VOLTAGE_BELOW_PAUSE_CHARGING, ignition) | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					
 | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					    while ssb < offroad_timestamp + DELAY_SHUTDOWN_TIME_S: | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					      self.assertFalse(pm.should_shutdown(ignition, in_car,  | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					                                          offroad_timestamp,  | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					                                          started_seen),  | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					                       f"Should not shutdown before {DELAY_SHUTDOWN_TIME_S} seconds offroad time") | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					    self.assertTrue(pm.should_shutdown(ignition, in_car,  | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					                                       offroad_timestamp,  | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					                                       started_seen), | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					                    f"Should shutdown after {DELAY_SHUTDOWN_TIME_S} seconds offroad time") | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					
 | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					
 | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					if __name__ == "__main__": | 
				
			
			
		
	
		
			
				
					 | 
					 | 
				
				 | 
				 | 
				
					  unittest.main() | 
				
			
			
		
	
	
		
			
				
					| 
						
						
						
					 | 
				
				 | 
				 | 
				
					
  |